Gas Appliance Regulator Installation
Second stage regulator installation.
Gas appliance regulator installation. Determining total load is the sum of all propane gas used in an installation and is expressed in btu s british thermal units. This is done by adding the btu input of all appliances being used. The drawing below is from the international residential code and offered as a visual aide to show the above sediment trap descriptions. Gas pressure regulator for liquefied propane and natural gas easy to install.
Second stage regulators are installed away from the tank often on the outside wall of a building or near the propane gas appliance such as an outdoor pool. The purpose of this information sheet is to provide for industrial and commercial installations a consistent approach to. For more information visit maxitrol appliance pressure regulator and vent limiter. Location of appliance isolating valves and consumer piping regulators.
The gas supply is connected to the tee s horizontal tap outlet the gas appliance is connected to the tee s top opening a nipple is installed into the tee s bottom opening and is capped. Maxitrol s 325 l series line pressure regulators are certified ansi z21 80 csa 6 22 in 2 psi and 5 psi systems when installing with an overpressure protection device opd. Gas information sheet 30. The 325 series regulator with a vent limiter will reduce the pressure to the rated inlet pressure range of the gas appliance regulator.
The regulator not only acts as a control regarding the flow and distribution of propane but also as a safety. We use line pressure regulators in a building s gas distribution system and install them between the service regulator and the gas appliance s pressure regulator. Gas pressure regulator gasland chef 1 2 npt in out gas pipe 1 2 psi 3 5 kpa gas inlet lpg10 wc. The myfire puck an important addition to the gv60 symax south field michi gan july 23 2019 the myfire puck is.
Propane regulator the heart of the lp gas system. The underlying principle with regard to tank regulator installation is to protect the regulator s vent from anything that could enter through the vent. The 325 must be installed at or near the appliance. Gas appliance line pressure regulators manufacturing company certifications ansi z21 80 cga 6 22 line pressure regulators ansi z21 18 cga 6 3 gas appliance pressure regulator notes regulators must be horizontally installed with the vent limiter upwards to ensure correct operation of the vent limiter.